INADVERTENT INTRA-ARTERIAL DIALYSIS CATHETER INSERTION INTO COMMON CAROTID ARTERY WITH SUCCESSFUL ENDOVASCULAR KISSING STENT INSERTION

WCN23-0988
Kidney Failure (Former ESKD), incl. Dialysis, Transplantation, Conservative Care
 
 
Haemodialysis, Haemodiafiltration and Vascular Access
 
 
INADVERTENT INTRA-ARTERIAL DIALYSIS CATHETER INSERTION INTO COMMON CAROTID ARTERY WITH SUCCESSFUL ENDOVASCULAR KISSING STENT INSERTION
Mohammad Kazmin, N.E.(1)*;Mustafar, R.(2);Wan Daud, W.R.(2);Mohd, R.(2);Kamaruzaman, L.(2);Fong, V.K.(2);Zainal, I.A.(3);Nik Ismail, N.A.(3);Haron, H.(4);Abdul Razak, N.Z.(5);Abdul Gafor, A.H.(2);
ie: Azwin Z.1, Siti Y.1, John D.2
(1)Universiti Sains Islam Malaysia, Faculty Of Medicine Of Health Sciences, Nilai, Malaysia;(2)Hospital Canselor Tuanku Muhriz- Ukm, Nephrology Unit- Department Of Medicine, Kuala Lumpur, Malaysia;(3)Hospital Canselor Tuanku Muhriz- Ukm, Department Of Radiology, Kuala Lumpur, Malaysia;(4)Hospital Canselor Tuanku Muhriz- Ukm, Department Of Surgery, Kuala Lumpur, Malaysia;(5)Malaysian Armed Forces Health Services, Department Of Medicine, Kuala Lumpur, Malaysia;
https://storage.unitedwebnetwork.com/files/1041/46abc8d06d1cb4307b8bcd88db3a01e3.pdf
 